tool to "Connect" and pull SDR files from the total station. Formatting:

: Originally designed for older Windows versions (95/98/XP), but can run on Windows 10/11 using compatibility mode. Connectivity sokkia prolink version 115

| Error Message | Likely Cause | Solution | | :--- | :--- | :--- | | "Instrument not responding" | Wrong COM port or cable missing TX/RX crossover. | Use a null modem adapter. ProLink expects a straight-through cable, but many USB adapters are crossover. | | "Timeout during firmware upload" | USB power saving is on. | Go to Device Manager > USB Root Hub > Properties > Power Management > Uncheck "Allow the computer to turn off this device." | | "Checksum error" | Noise on the line (long cable). | Reduce cable length to < 3 meters (10 ft). Drop baud rate to 9600. | tool to "Connect" and pull SDR files from the total station